Spécifications du fabricant - e.cam Duet, Siemens
Nous vous signalons que: None of the equipment posted for sale on MedWOW.com is owned by MedWOW, should you have any questions regarding a specific item, please direct them to the appropriate seller by making use of the available communication channels on the items page.

| MODEL | E.CAM Duet |
| SPECT (PROCESSOR) | Yes |
| OPTIONAL ATTACHMENTS (SHOCK-WAVE GENERATOR) | Pediatric and scintimammography pallets, flash 3-D advanced SPECT interactive reconstruction software, coincidence imaging, profile attenuation correction, automatic image fusion 3 |
| SYSTEM SPECIFICATIONS | SPECTDual detector, variable angle Also CT based attenuation correction software for SPECT and coincidence scans and e.soft@LEONARDO multimodality workspace. |
| HUMIDITY | 15-80% |
| DETECTOR CHARACTERISTICS | |
| Crystal dimensions, cm (in) (DETECTOR CHARACTERISTICS) | 59.1 x 44.5 (23.3 x 17.4) |
| Thickness, mm (in) (DETECTOR CHARACTERISTICS) | 25.4 (1) segmented |
| Number of pmts (DETECTOR CHARACTERISTICS) | 53 (3"), 6 (2") 1 |
| Size, cm (in) (MAXIMUM OBJECT) | 7.6 (3), 5 (2) Per detector. |
| Digital detectors (DETECTOR CHARACTERISTICS) | ADC on each PMT |
| FDG-SPECT | Optional |
| DETECTOR/YOKE MOVEMENT | |
| Whole-body scan | |
| Rate, cm/min (Whole-body scan) | Above 200 cm/min0.1-240 |
| Mode (IMAGING SYSTEM) | Single pass |
| Area, cm (Whole-body scan) | 52.8 x 202 |
| Contouring (Whole-body scan) | Automatic |
| Yoke rotation, deg (Whole-body scan) | 440 CW, 30 CCW |
| Radius, cm (in) (Whole-body scan) | 14 min to 67 max LEHR collimator |
| Detector turning, deg (Whole-body scan) | 20 cephalic in, 90 caudal out |
| Clearance | |
| Maximum, cm (in) (Clearance) | 67 (26.4) LEHR |
| Minimum, cm (in) (Clearance) | 9.0 (3.5) HE |
| OPERATING PANEL | |
| Persistence scope (OPERATING PANEL) | Yes |
| Zoom regulation (OPERATING PANEL) | Yes |
| Ratemeter | Yes |
| Scaler (OPERATING PANEL) | Yes |
| Time display (OPERATING PANEL) | Yes |
| Energy selection | |
| Automatic (CALIBRATION) | Yes |
| Manual (CALIBRATION) | Yes |
| Auto peaking (Energy selection) | Yes |
| Image turning control (Energy selection) | Yes |
| Pha window capacity (Energy selection) | 6 energy windows |
| Window selection | |
| Automatic (CALIBRATION) | Yes |
| Manual (CALIBRATION) | Yes |
| Auto uniformity correction (Window selection) | Yes |
| Nonuniform attenuation correction (Window selection) | Opt PROFILE w/Gd-153 multiple-line array |
| Collimators | LEHS, LEAP, LEHR, LEFB (fanbeam), HE, UHE, pinhole, MELP |
| SYSTEM FUNCTIONS | |
| Ufov, cm (in) (SYSTEM FUNCTIONS) | 52.8 x 37.7 (20.8 x 14.8) |
| Max. count,cps (SYSTEM FUNCTIONS) | 275000without scatter |
| Energy range, kev (SYSTEM FUNCTIONS) | 50-613 Per detector. |
| Intrinsic spatial resolution, mm | |
| Fwhm, ufov (Intrinsic spatial resolution, mm) | <=5.6 |
| Fwtm, ufov (Intrinsic spatial resolution, mm) | <=10.6 |
| Extrinsic spatial resolution (leap) | |
| Fwhm at 10 cm, mm (Extrinsic spatial resolution (leap)) | 8.5 with LEHR |
| Fwtm at 10 cm, mm (Extrinsic spatial resolution (leap)) | 16 with LEHR |
| System sensitivity, leap, counts/min/uci (Extrinsic spatial resolution (leap)) | 230 with LEHR 1 |
| Intrinsic energy resolution, fwhm, 140 kev (Extrinsic spatial resolution (leap)) | <=11.5% Per detector. |
| Intrinsic spatial linearity, mm | |
| Integral ufov (Intrinsic spatial linearity, mm) | <=1.5 absolute |
| Differential ufov (Intrinsic spatial linearity, mm) | <=0.35 |
| Intrinsic uniformity, uncorrected | |
| Integral ufov (Intrinsic spatial linearity, mm) | <=3.7% corrected |
| Differential ufov (Intrinsic spatial linearity, mm) | <=2.7% corrected |
| TOTAL BODY | Yes |
| PROCESSOR | |
| DATA INPUT | At camera statione. soft A |
| Processing (PROCESSOR) | e. soft P |
| Data transfer (PROCESSOR) | DICOM, TCP/IP |
| Dicom 3.0 (PROCESSOR) | Standard |
| Display matrix (IMAGE DISPLAY) | 1280 x 1024 |
| Storage | 40 GB OS data, 80 GB patient data |
| HEAT LOADING, BTU/hr (gantry only) (PROCESSOR) | 6800 |
| STABILITY (max °C change/hour) (PROCESSOR) | 4.4 |
| COINCIDENCE IMAGING | Optional |
| POWER NEEDED | 200-240 ±10% VAC, 50/60 Hz, single phase |
| DIMENSIONS (HXWXD), CM (IN) (DETECTION PROCESS, HR) | 193 x 167.6 x 169.5 (76 x 66 x 66.8) |
| WEIGHT, kg (lb) (DISPLAY) | 1,755 (3,900) 2 |
| CLINICAL USES | General-purposewith 2 HE collimators |
| OTHER ATTRIBUTES (Interference compensation) | SPECT with 76, 90, and 180° detector orientations, PET-based coincidence imaging w/measured random correction, 0.1" low attenuation imaging pallet, auto body contouring, user configurable workflow/display, connectivity to PACS/ HIS/RIS via DICOM worklist/ |
| FDA CLEARANCE (Interference compensation) | Yes |
| CE MARK (MDD) (Interference compensation) | Yes |
| WHERE MARKETED | Worldwide |
Les spécifications du fabricant ci-dessous vous intéressent peut-être:
- e.cam Multiangle Cardiac Spécifications du fabricant
- e.cam Variable Angle Spécifications du fabricant
- e.cam Single Spécifications du fabricant