Spécifications du fabricant - IntelliVue MP60/MP70 (M8005A/M8007A), Philips

Nous vous signalons que: None of the equipment posted for sale on MedWOW.com is owned by MedWOW, should you have any questions regarding a specific item, please direct them to the appropriate seller by making use of the available communication channels on the items page.
MODEL

IntelliVue MP60_MP70 (M8005A_M8007A)

PARAMETERSECG, NIBP, SpO2ECG/HR, 12-lead ST seg, IBP, temp, pulse, resp, NIBP, SpO2, tcpO2/tcpCO2, ms/ss ETCO2, anesthetic gas
Ecg (PARAMETERS)
Hr display, bpm (ECG)15-350
Precision (WAVELENGTH, nm)1%
ALERTS (CONFIGURATION)Yes
Number of simultaneously displayed leads (ECG)12+ 1 rhythm
Arrhythmia detect (ECG)Yes(multilead)
St analysis (ECG)Up to 12 channels
Auto lead switch (ECG)Yes
POWER NEEDED, VAC (ENERGY)100-240
AGE GROUPAdult to neonatal
NETWORKINGYes
Hardwired/wireless (ECG)Both
Max no. of beds (ECG)128/subnet, 10 subnets
Peripherals interface (PULSE OXIMETRY)VueLink (4 simultaneous connections to bedside devices) 3
TEMPERATUREComprehensive device library, RS232 interface, nurse-call relay, video interfaces; IntelliVue-only parallel printer interface.
Number of inputs (PROBE)1
Kind of probe (TEMPERATURE)Skin, rectal, esophageal
DISPLAYXGA TFT flat-panel, touch user interface
Size, cm (in) (MAXIMUM OBJECT)38.1 (15)
Traces (AUXILIARY OUTPUT)4,6, 8 (MP70 only)
RECORDER TYPE (AUXILIARY OUTPUT)Modular/central
Channels (POWER NEEDED)3
PULSE OXIMETRY
Kind of probe (TEMPERATURE)Nellcor Oximax or OxiSensor II, Masimo LNOP, Philips
Disposable/reusable (PULSE OXIMETRY)Yes/yes Motion-tolerant FAST SpO2.
Trending (DISPLAY)
PARAMETERSAll vital signs
Graphical/tabular (TRENDING)Yes/yes
Duration.hr (TRENDING)1/2/8 @ 12 sec;16/24 @ 1 min; 48 @ 5 min
NIBP
Cuff size (NIBP)Large, small, and standard adult; ped, infant, thigh
Hose connection (NIBP)Quick connect
Respiration (CHANNEL MEASUREMENTS)
TECHNIQUEImpedance (ECG), CO2
Waveform displayed (RESPIRATION)Yes
Threshold control (RESPIRATION)Yes
IBP
Number of channels (RECORDER)1
Scales range, mm hg (IBP)-40 to +360
Labels (IBP)Yes
ALERTS (CONFIGURATION)Yes
AUXILIARY OUTPUT
Defib/synch (AUXILIARY OUTPUT)Yes
Bp (AUXILIARY OUTPUT)Yes
Dimensions (hxwxd) cm (in) (GENERATOR)360 x 408 x 170 (14.2 x 16.1 x 7)
WEIGHT, kg (lb) (DISPLAY)<10 (<22) basic version
MODULAR/CONFIGURED (AUXILIARY OUTPUT)Modular 1
OTHER ATTRIBUTES (Interference compensation)Portal technology (e.g., x-ray images, lab results at the bedside); multiple flexible screen layouts; choice of user interface (with PS/2 connectors); conventional and EASI 12-lead; event surveillance for user-defined event capturing; clinical calcs; micr
FDA CLEARANCE (Interference compensation)Yes
CE MARK (MDD) (Interference compensation)Yes
MARKETING REGION (Interference compensation)Worldwide
Les spécifications du fabricant ci-dessous vous intéressent peut-être:
Responsabilité

L'information contenue dans cette page pourrait être partielle, incomplète, ou contenir des erreurs et des informations inexactes.
MedWOW décline toute responsabilité ou obligation qui dépendrait du contenu de cette page.


Moniteur patient, Philips, IntelliVue MP60/MP70 (M8005A/M8007A)
View More Items