Accélérateur linéaire - Varian -  Clinac 600C

Article 144154694

Vous êtes le vendeur de cet article? Connexion pour bénéficier d'options supplémentaires.
Statut: Disponible
Type d'Article: Système complet
Catégorie: Oncologie
Appareil: Accélérateur linéaire
Fabricant: Varian
Modèle: Clinac 600C
Condition: Tel quel
Année de fabrication: 1995
Emplacement: États-Unis, Connecticut
Disponibilité: Immédiatement
Quantité: 1 Disponible
Prix à l'unité: 35,000.00 USD
Contacter le vendeur
Inspecter avant d'acheter
Description de l'Article
VARIAN, 600C w/ 2002 BrainLAB M3 MLC Radiosurgery

Description: Varian 600C plus 2002 BrainLab M3 MLC
Stereotactic Radiotherapy
600C Installed June 1995

Console Software V. 5.4

TOTAL PRICE ONLY $35,000 FOR DEINSTALLED UNIT-- AN UNHEARD OF PRICE FOR A UNIT WHICH INCLUDES THE TOTAL DEINSTALATION COST &
THE COST OF ORIGINAL BASE FRAME REMOVAL WITH THE BASE FRAME INCLUDED IN SALE
--READY TO LOAD LINAC & BASE FRAME ON TRUCK along with 2002 BRAINLAB M3 MLC: Being sold w/ 2002 BrainLAB M3 stereotactic unit
Photon Energy: 6 MV
Beam Hours: <1,300
Dual jaws
ETR Couch
Unit in good working order at time of deinstallation
De-installed Base Frame [Conventional] included
Call to discuss details


SYSTEMS BROKERED have been CRATED and SHIPPED to SATISFIED CLIENTS AT CANCER CENTERS in
INDONESIA, TURKEY, BRAZIL, COLOMBIA, URUGUAY, RUSSIA, and other locations, and to therapy centers, and service companies in the US

REFERENCES AVAILABLE UPON REQUEST.

The m3 high-resolution multileaf collimator, with its fine 3mm leaves at isocenter, has revolutionized radiosurgery by introducing conformal treatments that tailor the dose to the shape of the tumor.

The m3 enables the delivery of superior homogeneous dose distributions with a steep dose gradient – an essential requirement for SRS treatments.

The leaves of the m3 are automatically placed around the target for all beam angles with the desired margin. Risk objects may be automatically protected by the leaves, with manual adjustments able to be made at any time.

Reduced irradiation of normal tissue and the homogeneous dose distribution within the PTV contributes to superior and more efficient patient care.

m3 SETUP
The detachable 'plug and treat' design of the m3 high-resolution multileaf collimator allows fast and easy slide-on attachment to almost any existing linac accessory mount, aided by the storage trolley and with the gantry at the 180° position.

Once m3 is physically mounted to the linear accelerator, the electrical and date connection is immediate.

INTEGRATED SAFETY
The m3 is the only solution fully integrated with Varian accelerators. It communicates with Varian C-Series Clinacs as if it were an internal part of the accelerator, providing superior Clinac safety interlocks, reliability and capabilities such as Dynamic Conformal Arcs and Dynamic IMRT.

Steep dose fall-off - a fundamental requirement for radiosurgery

Multileaf collimators with a leaf thickness of 10 mm are optimized for standard radiotherapy. For stereotactic treatments, a steep dose fall-off is required to protect normal tissue and, in particular, critical structures from high doses.

To accommodate a higher resolution dose delivery, new multileaf collimator designs with 5 mm thick leaves allow the delivery of fractionated stereotactic radiotherapy, but are not generally acceptable for single fraction radiosurgery where special requirements have been defined by the AAPM (1).

The steepness of the dose gradient in radiosurgery is a function of beam geometry and beam penumbra.

Care must be taken to minimize penumbra of the collimator system because the larger the beam penumbra, the shallower the dose fall-off (Figure 1).

For radiosurgery, the recommended limit for dose gradient in the beam penumbra (from 80% to 20%) is greater than or equal to 60%/3 mm (Figure 1).

Fig. 2* [See webpage link supplied for Figures]

Most commercially available multileaf collimators have a penumbra specification from 4 to 8 mm. The m3 with its 3 mm-thin leaves has an effective penumbra of less than 3 mm for all SRS field sizes and meets all SRS requirements (Figure 2).

Thus, the dose can be tailored according to the shape of the lesion, while sparing large amounts of normal healthy tissue.

*An irregular field shape formed from diagonal, straight field edges. Measured 80%, 50% and 20% isodose lines are indicated. A sinusoidal variation in the isodose lines occurs due to the stepping effect between leaf ends and is smallest where the field is formed by the 3 mm thin leaves. Tangents between the 80% and 20% isodose lines show an increasing effective penumbra with increasing leaf thickness.

REFERENCES

AAPM Report No. 54, Stereotactic Radiosurgery, Report of Task Group 42, American Institute of Physics, June 1995 Pike, Podgorsak, et. al., 'Dose distributions in radiosurgery' Medical Physics, Mar/Apr 1990 Cosgrove, et. al., 'Commissioning of a Micro Multi-leaf Collimator and Planning System for SRS.', Radiotherapy & Oncology, (50) 1999

Find your Solution: neurosurgery solutions orthopedic solutions RT/oncology solutions ent solutions spine & trauma solutions integrated OR solutions healthcare IT solutions home print send back m3 High-Resolution Multileaf Collimator
 Questions et Réponses Concernant cet Article 
 
QuestionRépondre
General: L’appareil fonctionnait-il conformément à la fiche technique du fabricant, juste avant d’être démonté ? En attente de confirmation
General: Le processus de remise en état a-t-il été effectué par le fabricant ou par son agent attitré ? En attente de confirmation
General: L’appareil est-il encore monté ? En attente de confirmation
General: Quelle est la date de la remise en état ? En attente de confirmation
General: Etes-vous le propriétaire de l’appareil ? En attente de confirmation
General: Y a-t-il des dégâts visibles ou non visibles ? En attente de confirmation
General: Alimentation - phase En attente de confirmation
General: Alimentation - tension En attente de confirmation
General: Le prix inclue-t-il l’emballage en caisse de l’appareil ? En attente de confirmation
General: Le système/matériel est-il entièrement homologué FDA ? En attente de confirmation
General: Le système/matériel porte-t-il le cachet "EC" ? En attente de confirmation
Manuals & Documentation: Y a-t-il un mode d’emploi ? En attente de confirmation
Manuals & Documentation: Y a-t-il un dossier de calibrage et réglage ? En attente de confirmation
Manuals & Documentation: Y a-t-il un dossier de plaintes des clients (DPC) ? En attente de confirmation
Manuals & Documentation: Y a-t-il un journal des activités d’entretien ? En attente de confirmation
Manuals & Documentation: Y a-t-il un journal des pièces changées ? En attente de confirmation
Does M3 come with plan software? How much for M3 only?
Informations sur la Vente
Paiement
Modes de paiement: Virement bancaire
Paiement d'un pourcentage à l'avance: 10%
Emballage
Cet article n'est pas emballé
Inspection
Le vendeur permet-il de faire une inspection pour cet article? Oui
Inspection disponible à partir de: Immédiatement
 
Les informations contenues dans cette page ont été fournies par le vendeur et par conséquent MedWOW ne peut pas garantir leur authenticité.
Vous ne trouvez pas ce que vous cherchez ? Publier une Demande d'achat
Nos Contacts d'achat vous permettent d'atteindre des vendeurs dans le monde entier !
  • Remplissez un formulaire simple, en nous donnant davantage de détails sur l'article que vous recherchez.
  • Vous recevrez des devis de vendeurs du monde entier.
  • Choisissez le devis le plus avantageux pour vous!
Publier une Demande d'achat >>

Voir davantage Accélérateur linéaire appareils en vente


Accélérateur linéaire peut aussi être nommé: unité de radiothérapie, accélérateur linéaire
Détails du vendeur
Emplacement: États-Unis, Connecticut
Type d'entreprise: Commerçant
En savoir plus sur ce vendeur
Recevoir un rapport d'activités D&B >>
Options de l'Acheteur
Options pour cet article